Effect of the Magnetic Fuel Treatment Device on Some Water Properties

Authors : Qater Al-Nada Ali Kanaem AL-Ibady

Abstract: The present study occurrence of significantly increased in boiling degree rates (the temperature) for water when exposed to magnetic treatment device of water in different intensities which were 22.3, 22.6 and 22.5°C in the magnetically water with 500, 1000 and 1500 G intensities in respectively, especially in 8-10 weeks, compared with untreated water magnetically which were 17.2°C. As well as significantly increased the value of alkalinity of water (pH-value) an increase of magnetic intensity hanging over the water which were 9.82, 9.5 and 9.54 in 500 G in 9th week, 1000 G in the 2nd week and 1500 G in the 2nd week too in respectively, compared with untreated magnetized water which were 8.41, also in the 2nd week. Also, increased significantly oxygen saturation rates (oxygen dissolved in water) which were 11.8 mg/L in the Ist week, 12.1 mg/L in the 8th week and 12.2 mg/L in the Ist week for magnetized water with 500, 1000 and 1500 G in respectively an increase of magnetic intensity, especially, intensity 1500 G, compared to the rest of magnetic intensities and untreated water magnetically which was 9.2 mg/L in the 9th week. In that experience happened an increase in the electrical conductivity (specific conductance) in the treated water, it increased its value of electrical conductivity of water an increase of magnetic intensity which respectively, 794 μsec/cm in 6th week, 797 μsec/cm in the 6th week and 799 μsec/cm in the 6th week also, compared with untreated water which were 651 μsec/cm in the 3rd week. As well as those in that experience, found the highest increase in the significant in water soluble salts (total dissolved solids), especially in 1500 G intensity which were 539 ppm in the 6th week, 540 ppm in the 6th week and 545 ppm in the 6th week too of intensities 500, 1000 and 1500 G in respectively, compared with no magnetized water (untreated water) which was the less value 426 ppm in the 3rd week. All these experiences were under the level probability of <0.05 under the laboratory conditions.

How to cite this article:

Qater Al-Nada Ali Kanaem AL-Ibady , 2018. Effect of the Magnetic Fuel Treatment Device on Some Water Properties. Journal of Engineering and Applied Sciences, 13: 10747-10753.

Design and power by Medwell Web Development Team. © Medwell Publishing 2024 All Rights Reserved